Description
Agni 10 Zone Annunciator Panel
Overview
The Agni 10 Zone Annunciator Panel is a microprocessor-based remote indication panel designed to provide clear, real-time visual status of all zones in a fire alarm system. Manufactured by Agni — a trusted name in fire safety solutions with ISI/ERTL certifications and compliance with Indian standards — this annunciator panel offers reliable zone-wise indication for fire, fault, open, short, and isolate conditions, enabling first responders and building personnel to quickly identify the exact location of an emergency.
An annunciator panel serves as a remote repeater or status display unit, typically installed at the building’s main entrance, security desk, or fire control room. This allows fire wardens, security personnel, and emergency responders to instantly assess the fire situation without accessing the main fire alarm control panel. The Agni 10 Zone Annunciator Panel provides a clear, intuitive interface with LED indicators and a backlit LCD display, ensuring that critical information is always visible and easy to understand.
Whether you’re equipping a commercial complex, a residential building, an educational institution, or a healthcare facility, the Agni 10 Zone Annunciator Panel delivers the reliability, clarity, and performance you need for effective fire emergency management.
Key Features
| Feature | Description |
|---|---|
| 10 Zone Indication | Clear zone-wise visual status for up to 10 zones, enabling quick identification of fire or fault locations |
| Microprocessor-Based Control | Intelligent processing ensures reliable and accurate zone status monitoring |
| Zone Wise Fire & Fault LED Indication | Individual LED indicators for each zone provide unambiguous status — fire, open circuit, short circuit, isolate, and normal conditions |
| 16×2 Character Backlit LCD Display | Alphanumeric display providing detailed system status information for complete zone health monitoring |
| Zone Isolation Facility | Isolate individual zones for maintenance or troubleshooting without affecting other zones |
| Inbuilt Buzzer | Audible alerts for fire and fault conditions, ensuring immediate awareness |
| Mains On, System On, Charger On Indications | Dedicated LED indicators for power and system status |
| External Switches | Manual controls for reset, silence, and lamp test for easy system operation |
| External Test Switches | Manual test functionality for each zone to verify fire, open, and short status |
| Auto Dialler Attachable Facility | Remote notification capability for off-site alerting |
| Potential Free Contact Facility | NO/NC relay contacts for integration with external systems and BMS |
| Repeater Panel Interface | Reserved interface for fire alarm indication of multiple zones |
| Inbuilt Battery Charger & Battery Space | Complete with integral power supply and battery charger for SMF battery backup |
| BMS Attachment | Building Management System integration capability |
| RS 485 Communication | 2-wire communication facility for remote connectivity |
| Event Logging Facility | 64/128/256 events logging with real-time clock and keypad (optional) |
Technical Specifications
| Parameter | Specification |
|---|---|
| Brand | Agni |
| Number of Zones | 10 |
| System Type | Microprocessor-based Conventional |
| Power Input | 230V AC, 50Hz ± 10% |
| Standby Voltage | 24V DC |
| Normal Loop Voltage | 12V DC |
| Power Consumption | 30W (Normal) / 200W (Fire) |
| End of Line Resistor | 4.7 kΩ |
| Detection Output Supply | 24V DC |
| Hooter Output Supply | 24V DC |
| Hooter Output | 0.7A (24V DC) Normal |
| Fire Contact | (C, NO, NC) 240V AC @ 2.5A / 24V DC @ 1.5A |
| Operating Temperature | 0°C to 40°C |
| Operating Humidity | Up to 95% (non-condensing) |
| Cabinet Material | MS / CRCA Sheet with Powder Coated Finish |
| Colour | Off-White Powder Coating |
| Knock Out | 20mm |
| Dimensions | 11″ × 13″ × 4″ |
| Weight | 5.2 kg (without battery) |
| Warranty | 12 Months |
| Country of Origin | Made in India |
Why Choose Agni 10 Zone Annunciator Panel?
-
IS 2189:1999 Compliant — Fully conforms to Indian standards for automatic fire alarm systems, ensuring quality and reliability
-
ERTL (N) & System Sensor Tested — Validated by the Electronics Regional Test Laboratory (North) and System Sensor for assured performance
-
Clear Zone Identification — Individual LED indicators and LCD display provide unambiguous status for each of the 10 zones, enabling rapid emergency response
-
Easy Operation — External switches for reset, silence, and lamp test simplify system operation
-
Remote Status Indication — Ideal for installation at building entrances, security desks, and fire control rooms for quick assessment by first responders
-
Enhanced System Reliability — Zone isolation facility allows maintenance without disrupting the entire system
-
Expandable Capabilities — Optional event logging, RS 485 communication, and BMS integration for advanced system requirements
-
Robust Construction — Rugged MS/CRCA cabinet with powder-coated finish ensures durability
-
Made in India — Proudly manufactured with quality craftsmanship
Ideal Applications
-
Commercial Buildings — Office complexes, shopping malls, retail spaces, and hotels
-
Residential Complexes — Apartments, housing societies, and gated communities
-
Educational Institutions — Schools, colleges, and universities
-
Healthcare Facilities — Hospitals, clinics, and nursing homes
-
Public Buildings — Auditoriums, theatres, airports, and community centres
-
Industrial Facilities — Factories, warehouses, and manufacturing plants
-
Hospitality Sector — Hotels, resorts, and restaurants
Compliance & Standards
| Standard | Description |
|---|---|
| IS 2189:1999 | Conforms to Indian standards for automatic fire alarm systems |
| ERTL (N) Tested | Validated by the Electronics Regional Test Laboratory (North) |
| System Sensor Compatible | Tested for compatibility with System Sensor devices |
For detailed product inquiries, technical support, or to place an order, please contact our sales team.







Reviews
There are no reviews yet.