Description
ISI-Certified 6mm Orifice Plate for Fire Protection Systems
Overview
The ISI-Certified 6mm Orifice Plate is a precision-engineered flow control device designed to regulate pressure and restrict flow in fire sprinkler and water pipeline systems. Manufactured in compliance with stringent Indian Standards, this orifice plate ensures reliable performance for critical safety applications where accurate flow measurement and pressure reduction are essential.
An orifice plate is a simple yet highly effective device consisting of a thin plate with a precisely machined hole . Operating on Bernoulli’s principle, it creates a controlled pressure drop that can be used to measure or restrict fluid flow . When fluid passes through the orifice, velocity increases while pressure decreases, allowing for accurate flow regulation .
The 6mm orifice plate is specifically designed for applications requiring moderate flow restriction, typically used in fire sprinkler systems, hydrant networks, and water distribution pipelines to balance flow rates and maintain optimal system pressure.
Key Features
| Feature | Description |
|---|---|
| Precision-Machined Orifice | Laser-cut central bore with accuracy of 0.1mm, ensuring consistent and repeatable flow control |
| ISI-Compliant Construction | Manufactured to meet Bureau of Indian Standards requirements for fire protection equipment |
| High-Quality Materials | Available in Stainless Steel (SS304/SS316), Brass, Hastelloy, Monel, and Alloy Steels for corrosion resistance and long service life |
| Multiple Configurations | Available as Concentric (for clean fluids), Eccentric (for fluids with solids or gas pockets), or Segmental (for slurry or dirty fluids) |
| High Pressure & Temperature Ratings | Suitable for operating pressures up to 400 bar and temperatures up to 800°C |
| Laser-Cut to Exact Specifications | Modern manufacturing techniques ensure precise dimensions and consistent quality |
| Custom Stamping/Engraving | Clear marking with size, orifice diameter, and K-factor for easy identification |
| Corrosion-Resistant Construction | Manufactured from non-corroding materials suitable for fire protection and industrial applications |
Technical Specifications
| Parameter | Specification |
|---|---|
| Orifice Size | 6mm (±0.1mm accuracy) |
| Plate Thickness | 3mm to 10mm (as per application requirements) |
| Line Size Compatibility | Suitable for nominal pipe diameters from 50mm to 200mm |
| Material Options | Stainless Steel (SS304/SS316), Brass, Hastelloy, Monel, Alloy Steels |
| Maximum Operating Pressure | Up to 400 bar |
| Maximum Operating Temperature | Up to 800°C |
| Measurement Accuracy | ±0.5% to ±3.0% (for flow measurement applications) |
| Configuration Types | Concentric, Eccentric, Segmental, Quadrant Edge, Restriction, Multihole |
| Compliance | ISI Standards, ISO, ASME, ANSI |
| Country of Origin | Made in India |
Available Configurations
| Type | Application |
|---|---|
| Concentric Orifice Plate | Standard design for clean fluids and general flow measurement |
| Eccentric Orifice Plate | Designed for fluids containing solids, gas pockets, or where debris may accumulate |
| Segmental Orifice Plate | Suitable for slurry, dirty fluids, and applications with suspended solids |
| Quadrant Edge Orifice Plate | For low Reynolds number flows and viscous fluids |
| Restriction Orifice Plate | Specifically designed for pressure reduction in pipelines |
Why Choose an ISI-Certified Orifice Plate?
-
Quality Assurance: Compliance with Indian Standards ensures that the orifice plate meets stringent material, dimensional, and performance requirements for fire protection applications
-
Precision Engineering: Laser-cut to 0.1mm accuracy guarantees consistent flow characteristics and reliable pressure drop calculations
-
Versatile Applications: Suitable for fire sprinkler systems, hydrant networks, industrial process lines, and water distribution systems
-
Durable Construction: Manufactured from corrosion-resistant materials to withstand demanding environments and extended service life
-
Cost-Effective Solution: Simple, robust design offers reliable performance at a fraction of the cost of complex flow control devices
-
Easy Installation: Designed to fit between standard flanges in pipelines, simplifying installation and maintenance
-
Custom Manufacturing: Available in various materials and configurations to suit specific application requirements
-
Trusted by Authorities: Compliance with ISI and international standards makes these plates widely accepted by municipal corporations, fire brigades, and industrial safety departments
Ideal Applications
-
Fire Sprinkler Systems — Flow balancing and pressure reduction in fire protection networks
-
Fire Hydrant Systems — Regulating flow rates in hydrant pipelines
-
Industrial Process Lines — Flow measurement and pressure control in water, chemical, and utility pipelines
-
Water Distribution Networks — Balancing flow rates in municipal water systems
-
HVAC Systems — Flow control in heating and cooling water circuits
-
Pump Discharge Lines — Preventing over-pressurization in pumping systems
-
Irrigation Systems — Flow regulation in agricultural water distribution
Compliance & Standards
| Standard | Description |
|---|---|
| ISI Standards | Bureau of Indian Standards requirements for fire protection equipment |
| ISO | International Standards Organization guidelines for orifice plate design |
| ASME | American Society of Mechanical Engineers standards for flow measurement devices |
| ANSI | American National Standards Institute specifications |
For detailed product inquiries, technical specifications, bulk order pricing, or to place an order, please contact our sales team.







Reviews
There are no reviews yet.