{"id":388,"date":"2026-06-14T11:28:44","date_gmt":"2026-06-14T11:28:44","guid":{"rendered":"https:\/\/redfire.co.in\/?post_type=product&#038;p=388"},"modified":"2026-06-27T13:50:55","modified_gmt":"2026-06-27T13:50:55","slug":"addressable-isolator","status":"publish","type":"product","link":"https:\/\/redfire.co.in\/?product=addressable-isolator","title":{"rendered":"Addressable Isolator"},"content":{"rendered":"<h1><span class=\"\">Morley Addressable Isolator Module (MI-DISO)<\/span><\/h1>\n<hr \/>\n<h2><span class=\"\">Overview<\/span><\/h2>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">The\u00a0<\/span><strong><span class=\"\">Morley Addressable Isolator Module (MI-DISO)<\/span><\/strong><span class=\"\">\u00a0is a loop-powered, intelligent short circuit isolation device engineered to protect Morley-IAS analogue addressable fire alarm systems against wire-to-wire short circuits on the analogue addressable loop wiring<\/span><span class=\"\">. Manufactured by\u00a0<\/span><strong><span class=\"\">Morley-IAS<\/span><\/strong><span class=\"\">\u00a0\u2014 a trusted brand under\u00a0<\/span><strong><span class=\"\">Honeywell<\/span><\/strong><span class=\"\">\u00a0with decades of fire safety expertise \u2014 this module ensures that a single cable fault does not disable the entire detection loop, maintaining system integrity and life safety when it matters most.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Designed to be strategically placed between groups of sensors on the loop wiring, the MI-DISO automatically isolates faulty sections of the loop, allowing the remainder of the system to continue functioning uninterrupted<\/span><span class=\"\">. When a short circuit fault occurs, the two isolators located on either side of the fault automatically sense the voltage drop, open their switches, and remove the affected devices from the rest of the loop<\/span><span class=\"\">. Once the fault is cleared and line voltage rises above a fixed threshold, the isolator module automatically restores power to the isolated group of devices<\/span><span class=\"\">.<\/span><\/p>\n<p class=\"ds-markdown-paragraph\"><span class=\"\">Whether you&#8217;re equipping a commercial building, an industrial facility, a hospital, or a residential complex, the Morley Addressable Isolator Module delivers the intelligence, reliability, and performance you need for robust fire protection with enhanced system resilience.<\/span><\/p>\n<hr \/>\n<h2><span class=\"\">Key Features<\/span><\/h2>\n<div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\">\n<div class=\"ds-scroll-area__gutters\">\n<div class=\"ds-scroll-area__horizontal-gutter\"><\/div>\n<div class=\"ds-scroll-area__vertical-gutter\"><\/div>\n<\/div>\n<table>\n<thead>\n<tr>\n<th><span class=\"\">Feature<\/span><\/th>\n<th><span class=\"\">Description<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong><span class=\"\">Automatic Short Circuit Isolation<\/span><\/strong><\/td>\n<td><span class=\"\">Automatically detects and isolates wire-to-wire short circuits on the analogue addressable loop, preventing total loop failure<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Intelligent Fault Restoration<\/span><\/strong><\/td>\n<td><span class=\"\">Automatically restores power to isolated devices once the short circuit fault is cleared<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Supports Up to 25 Devices<\/span><\/strong><\/td>\n<td><span class=\"\">Each isolator module can support up to 25 items maximum, providing flexible system design<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Unique Mechanical Design<\/span><\/strong><\/td>\n<td><span class=\"\">Allows each module to be mounted either in a standard wall box or on a 35mm DIN rail<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Visible &amp; Accessible Address Switches<\/span><\/strong><\/td>\n<td><span class=\"\">Address switches are visible and accessible in two planes without removing the mounting box cover, simplifying maintenance and fault finding<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Tri-Colour LED Status Indication<\/span><\/strong><\/td>\n<td><span class=\"\">Multi-colour LEDs provide clear diagnostic information regarding the status of the isolator \u2014 blinking in normal conditions and switching on\/off in the presence of a short circuit<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Plug-in Connectors<\/span><\/strong><\/td>\n<td><span class=\"\">Field wiring terminals of plug-in design for ease of installation, testing, and maintenance<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Low Standby Current<\/span><\/strong><\/td>\n<td><span class=\"\">Energy-efficient design with quiescent current of just 200 microA<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Loop Powered<\/span><\/strong><\/td>\n<td><span class=\"\">Powered directly from the analogue addressable loop (15-30V DC), eliminating the need for separate power supplies<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Wide Operating Temperature Range<\/span><\/strong><\/td>\n<td><span class=\"\">Operates reliably from -20\u00b0C to +60\u00b0C<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<hr \/>\n<h2><span class=\"\">Technical Specifications<\/span><\/h2>\n<div class=\"ds-scroll-area ds-scroll-area--show-on-focus-within ds-scroll-area--enabled _1210dd7 c03cafe9\">\n<div class=\"ds-scroll-area__gutters\">\n<div class=\"ds-scroll-area__horizontal-gutter\"><\/div>\n<div class=\"ds-scroll-area__vertical-gutter\"><\/div>\n<\/div>\n<table>\n<thead>\n<tr>\n<th><span class=\"\">Parameter<\/span><\/th>\n<th><span class=\"\">Specification<\/span><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong><span class=\"\">Brand<\/span><\/strong><\/td>\n<td><span class=\"\">Morley-IAS (Honeywell)<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Model Name\/Number<\/span><\/strong><\/td>\n<td><span class=\"\">MI-DISO<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">System Type<\/span><\/strong><\/td>\n<td><span class=\"\">Analogue Addressable<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Power Supply<\/span><\/strong><\/td>\n<td><span class=\"\">Loop Powered, 15-30V DC<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Quiescent Current<\/span><\/strong><\/td>\n<td><span class=\"\">200 \u00b5A<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Maximum Devices Supported<\/span><\/strong><\/td>\n<td><span class=\"\">25 items per isolator module<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Fault Detection Delay<\/span><\/strong><\/td>\n<td><span class=\"\">100 to 400 mS<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Terminal Wire Size<\/span><\/strong><\/td>\n<td><span class=\"\">2.5 mm\u00b2 maximum<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Dimensions (H x W x D)<\/span><\/strong><\/td>\n<td><span class=\"\">93 x 94 x 23 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Mounting Options<\/span><\/strong><\/td>\n<td><span class=\"\">Wall box mounting \/ 35mm DIN rail<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Operating Temperature<\/span><\/strong><\/td>\n<td><span class=\"\">-20\u00b0C to +60\u00b0C<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Operating Humidity<\/span><\/strong><\/td>\n<td><span class=\"\">Up to 95% RH (non-condensing)<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Status Indication<\/span><\/strong><\/td>\n<td><span class=\"\">Tri-colour LED<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Compatibility<\/span><\/strong><\/td>\n<td><span class=\"\">All Morley-IAS analogue addressable fire alarm control panels<\/span><\/td>\n<\/tr>\n<tr>\n<td><strong><span class=\"\">Certifications<\/span><\/strong><\/td>\n<td><span class=\"\">EN54-17:2005 Certified<\/span><span class=\"\">, GEA GEI 1-082 &amp; CEA GEI 1-084 Approved<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<hr \/>\n<h2><span class=\"\">Why Choose Morley Addressable Isolator Module?<\/span><\/h2>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Trusted Global Brand<\/span><\/strong><span class=\"\">\u00a0\u2014 Manufactured by Morley-IAS, a Honeywell company with decades of fire safety expertise<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">EN54-17 Certified<\/span><\/strong><span class=\"\">\u00a0\u2014 Meets stringent European standards for fire alarm system components<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Enhanced System Reliability<\/span><\/strong><span class=\"\">\u00a0\u2014 Prevents a single short circuit from disabling the entire detection loop, ensuring continuous protection<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Automatic Operation<\/span><\/strong><span class=\"\">\u00a0\u2014 Fully automatic fault detection, isolation, and restoration without manual intervention<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Flexible Mounting Options<\/span><\/strong><span class=\"\">\u00a0\u2014 Unique design allows mounting in wall boxes or on DIN rails, suiting any installation requirement<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Easy Installation &amp; Maintenance<\/span><\/strong><span class=\"\">\u00a0\u2014 Plug-in connectors, visible address switches, and accessible LED indicators simplify setup and fault finding<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Compact &amp; Space-Saving<\/span><\/strong><span class=\"\">\u00a0\u2014 Slim form factor (93 x 94 x 23 mm) fits easily into devices, junction boxes, or control cabinets<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Low Power Consumption<\/span><\/strong><span class=\"\">\u00a0\u2014 Ultra-low standby current of 200 \u00b5A minimizes loop loading<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Made in India<\/span><\/strong><span class=\"\">\u00a0\u2014 Proudly manufactured with quality craftsmanship<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Extended Warranty<\/span><\/strong><span class=\"\">\u00a0\u2014 Covered by an extended warranty for peace of mind<\/span><\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h2><span class=\"\">Ideal Applications<\/span><\/h2>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Commercial Buildings<\/span><\/strong><span class=\"\">\u00a0\u2014 Office complexes, shopping malls, retail spaces, and hotels<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Industrial Facilities<\/span><\/strong><span class=\"\">\u00a0\u2014 Factories, warehouses, manufacturing plants, and data centers<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Healthcare Facilities<\/span><\/strong><span class=\"\">\u00a0\u2014 Hospitals, clinics, and nursing homes<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Educational Institutions<\/span><\/strong><span class=\"\">\u00a0\u2014 Schools, colleges, and universities<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Residential Complexes<\/span><\/strong><span class=\"\">\u00a0\u2014 Apartments, housing societies, and gated communities<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Public Buildings<\/span><\/strong><span class=\"\">\u00a0\u2014 Auditoriums, theaters, airports, and community centers<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Large-Scale Installations<\/span><\/strong><span class=\"\">\u00a0\u2014 Systems with extensive loop wiring where short circuit protection is critical<\/span><\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<h2><span class=\"\">Compliance &amp; Standards<\/span><\/h2>\n<ul>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">EN54-17:2005<\/span><\/strong><span class=\"\">\u00a0\u2014 Certified for fire alarm system components (0786-CPR-21643)<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">GEA GEI 1-082<\/span><\/strong><span class=\"\">\u00a0\u2014 Approved for specific applications<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">CEA GEI 1-084<\/span><\/strong><span class=\"\">\u00a0\u2014 Approved for specific applications<\/span><\/p>\n<\/li>\n<li>\n<p class=\"ds-markdown-paragraph\"><strong><span class=\"\">Class &#8216;B&#8217; Wiring<\/span><\/strong><span class=\"\">\u00a0\u2014 Supports supervised Class B wiring configurations<\/span><\/p>\n<\/li>\n<\/ul>\n<hr \/>\n<p class=\"ds-markdown-paragraph\"><em><span class=\"\">For detailed product inquiries, technical support, or to place an order, please contact our sales team.<\/span><\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p><span class=\"\">The\u00a0<\/span><strong><span class=\"\">Morley Addressable Isolator Module (MI-DISO)<\/span><\/strong><span class=\"\">\u00a0is a loop-powered, intelligent short circuit isolation device engineered to protect Morley-IAS analogue addressable fire alarm systems against wire-to-wire short circuits on the analogue addressable loop wiring<\/span><span class=\"\">. Manufactured by\u00a0<\/span><strong><span class=\"\">Morley-IAS<\/span><\/strong><span class=\"\">\u00a0\u2014 a trusted brand under\u00a0<\/span><strong><span class=\"\">Honeywell<\/span><\/strong><span class=\"\">\u00a0with decades of fire safety expertise \u2014 this module ensures that a single cable fault does not disable the entire detection loop, maintaining system integrity and life safety when it matters most.<\/span><\/p>\n","protected":false},"featured_media":441,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[33],"product_cat":[15],"product_tag":[],"class_list":["post-388","product","type-product","status-publish","has-post-thumbnail","product_brand-morlay","product_cat-uncategorized","first","instock","shipping-taxable","purchasable","product-type-simple"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/redfire.co.in\/index.php?rest_route=\/wp\/v2\/product\/388","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/redfire.co.in\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/redfire.co.in\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/redfire.co.in\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=388"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/redfire.co.in\/index.php?rest_route=\/wp\/v2\/media\/441"}],"wp:attachment":[{"href":"https:\/\/redfire.co.in\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=388"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/redfire.co.in\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=388"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/redfire.co.in\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=388"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/redfire.co.in\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=388"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}